Part Number: 841795-01
Alternate P/N: 84179501
Manufacturer: Litton Systems Inc
NIIN: 013396647
CAGE Code: 13973
FSG: 59 Electrical and Electronic Equipment Components
Country: USA
NCB Code: 01

Are you in search of a reputable online distributor that can reliably source and ship top-notch military and defense parts, NSN parts, and aerospace parts? If so, we have you covered on Buy Mil-NSN Parts with our unrivaled inventory of offerings. Thank you for taking an interest in part number 841795-01, a Litton Systems Inc item that is listed alongside the description “Filter Radio Frequency Interfere” and the NSN 5915013396647. If you would like to learn more about this particular listing, you can always take the initial step of the procurement process via the submission of the quote request form on this page.

Note : We Will Not Share Your Information To Any Third Parties.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Upload RFQ SHEET

We organize our offerings in a variety of ways to make the search process simple for part number 841795-01 and other similar items. For instance, this Litton Systems Inc product is listed alongside the NSN 5915-01-339-6647, and it falls under Federal Supply Class (FSC) 5915 Filters and Networks. Furthermore, through our rigorous vetting processes, careful part inspections, document verification practices, and more, we have established ourselves as a trusted distributor operating with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. With all of this in mind, begin the procurement process for part number 841795-01 from CAGE Code 13973 on our website, and see why so many customers steadily depend on Buy Mil-NSN Parts for the NSN products they require.

NSN Information for Part Number 841795-01 with NSN 5915-01-339-6647, 5915013396647

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5915-01-339-6647

Item PartTypeName:

FILTER,RADIO FREQUENCY INTERFERE

59150133966470P
CIICHCCESDPMICCriticalityENAC
UA
Part NumberISCRNVCRNCCHCCMSDSSADC
841795-1693

Characteristics Data of NSN 5915-01-339-6647, 5915013396647

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH5.700 INCHES MAXIMUM
ADAUBODY HEIGHT2.000 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.320 INCHES NOMINAL
AGAVEND ITEM IDENTIFICATIONTACTICAL AIR OPERATIONS MODULE AN/TYQ-23(V)1
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 3RD RADIO INTERFERENCE AND 0.05 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 6TH RADIO INTERFERENCE AND 0.1 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE13973
AHBSOUTPUT TERMINAL MANUFACTURER CODE13973
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE125.0 VOLTS AT SEA LEVEL
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 2ND RADIO INTERFERENCE AND 50.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 4TH RADIO INTERFERENCE AND 50.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 6TH RADIO INTERFERENCE AND 50.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE125.0 VOLTS AT SEA LEVEL
CTJSUNPACKAGED UNIT WEIGHT4.410 POUNDS NOMINAL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 3RD RADIO INTERFERENCE 3RD FUNCTION
AHCGMAXIMUM TEMP RISE25.0 DEG CELSIUS
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS3.0 AND 10.0 AND 40.0 AND 60.0 AND 70.0 AND 90.0
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 1ST RADIO INTERFERENCE AND 50.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 3RD RADIO INTERFERENCE AND 50.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQJXNOMINAL THREAD SIZE0.190 INCHES
CQRGBODY MATERIALMETAL
ADAQBODY LENGTH5.000 INCHES MAXIMUM
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 1ST RADIO INTERFERENCE AND 0.05 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 4TH RADIO INTERFERENCE AND 0.05 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 5TH RADIO INTERFERENCE AND 0.1 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
ABKWOVERALL HEIGHT2.700 INCHES MAXIMUM
ADATBODY WIDTH4.620 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-28.0 TO 85.0 DEG CELSIUS
AFSVAVERAGE LIFE RATING IN HOURS1000.0
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 2ND RADIO INTERFERENCE AND 0.05 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBPINPUT TERMINAL IDENTIFICATIONBNC-CONNECTOR
AHBTOUTPUT TERMINAL IDENTIFICATIONBNC-RECEPTACLE
AKNAINCLOSURE TYPEHERMETICALLY SEALED
CBBLFEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 CONNECTOR,PLUG INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 5TH RADIO INTERFERENCE AND 50.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
CRSTBODY SURFACE TREATMENTTIN
FEATSPECIAL FEATURESTWENTY-TWO FILTERED FUNCTIONS

Related NSN Components of 841795 01

A Complete NSN Part Purchasing Platform

  • AS9120B and ISO 9001:2015 Certified
  • Aviation Suppliers Association Member
  • FAA AC 0056B Accredited
  • AS 6081:2012 Certified
  • ESD S20.20-2014 Certified

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top