Are you in search of a reputable online distributor that can reliably source and ship top-notch military and defense parts, NSN parts, and aerospace parts? If so, we have you covered on Buy Mil-NSN Parts with our unrivaled inventory of offerings. Thank you for taking an interest in part number BX-9383, a Baltimore Transformer Company item that is listed alongside the description “Transformer Power” and the NSN 5950009463305. If you would like to learn more about this particular listing, you can always take the initial step of the procurement process via the submission of the quote request form on this page.
Note : We Will Not Share Your Information To Any Third Parties.
We organize our offerings in a variety of ways to make the search process simple for part number BX-9383 and other similar items. For instance, this Baltimore Transformer Company product is listed alongside the NSN 5950-00-946-3305, and it falls under Federal Supply Class (FSC) 5950 Coils and Transformers. Furthermore, through our rigorous vetting processes, careful part inspections, document verification practices, and more, we have established ourselves as a trusted distributor operating with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. With all of this in mind, begin the procurement process for part number BX-9383 from CAGE Code 85323 on our website, and see why so many customers steadily depend on Buy Mil-NSN Parts for the NSN products they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-946-3305 Item PartTypeName: TRANSFORMER,POWER | 5950 | 009463305 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ST 28978 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.190 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.210 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.510 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.530 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO TWO PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA |
ADAQ | BODY LENGTH | 2.860 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.250 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.300 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.02 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 11.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 825.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 38.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 133.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.638 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 22.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 26.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 9.3 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 19.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 54.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 70.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 94.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 114.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 3.47 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 58.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS WITH FIRST,SECOND,FOURTH,AND FIFTH WINDINGS CENTER TAPPED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 23 TAB,SOLDER LUG |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.