MRC | Criteria | Characteristic |
---|
AHRW | TUBING TWIST TYPE | STRAIGHT TWIST THIRD TUBING SEGMENT |
AHRX | TUBING TWIST ANGLE IN DEG | 90.0 THIRD TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM ALL FLANGES AND 0.904 INCHES MAXIMUM ALL FLANGES |
FLEX | FLEXIBILITY | RIGID FOURTH TUBING SEGMENT |
PMLC | PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED THIRD TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSY | FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM ALL FLANGES AND 0.404 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM ALL FLANGES AND 1.640 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM ALL FLANGES AND 0.453 INCHES MAXIMUM ALL FLANGES |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
CTFP | WAVEGUIDE SECOND LEG LENGTH | 2.260 INCHES NOMINAL |
CWBP | WAVEGUIDE THIRD LEG LENGTH | 3.350 INCHES NOMINAL |
FLEX | FLEXIBILITY | FLEXIBLE THIRD TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SECOND TUBING SEGMENT |
PRMT | PRECIOUS MATERIAL | SILVER |
STYL | STYLE DESIGNATOR | FOUR BEND TYPE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIP. |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJF | THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SECOND TUBING SEGMENT |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM ALL FLANGES AND 1.640 INCHES MAXIMUM ALL FLANGES |
AHTX | INSERTION LOSS IN DECIBELS | 0.15 |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
CSRM | WAVEGUIDE FIRST LEG LENGTH | 2.260 INCHES NOMINAL |
CTCJ | FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | SILVER ALL TUBING SEGMENT INSIDE SURFACES |
THSD | THREAD SERIES DESIGNATOR | UNC ALL FLANGES ALL CONNECTION FACILITIES |
AAJD | THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FOURTH TUBING SEGMENT |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.35 |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
CSRN | WAVEGUIDE FIFTH LEG LENGTH | 6.000 INCHES NOMINAL |
CXBG | WAVEGUIDE FOURTH LEG LENGTH | 5.060 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | FLANGES HAVE RESONANCE SUPPRESSOR AND CAPTURED SCREWS INCLUDED WITH EACH FLANGE |
SFTT | SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PASSIVATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PRIMER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |