MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B SECOND FLANGE SINGLE CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE SINGLE CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.279 INCHES MINIMUM SECOND FLANGE AND 0.281 INCHES MAXIMUM SECOND FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.362 INCHES MINIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.139 INCHES MINIMUM SECOND FLANGE AND 0.141 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.222 INCHES MINIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 0.735 INCHES MINIMUM SECOND FLANGE AND 0.765 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 0.745 INCHES MINIMUM FIRST FLANGE AND 0.755 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 0.735 INCHES MINIMUM SECOND FLANGE AND 0.765 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 0.745 INCHES MINIMUM FIRST FLANGE AND 0.755 INCHES MAXIMUM FIRST FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 0.485 INCHES MINIMUM SECOND FLANGE AND 0.515 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.182 INCHES MINIMUM FIRST FLANGE AND 0.192 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.195 INCHES MINIMUM SECOND FLANGE AND 0.225 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.116 INCHES MINIMUM FIRST FLANGE SINGLE CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AHTX | INSERTION LOSS IN DECIBELS | 0.40 |
CMLP | THREAD QUANTITY PER INCH | 40 SECOND FLANGE SINGLE CONNECTION FACILITY |
CQGM | MAXIMUM OPERATING PRESSURE | 30.0 POUNDS PER SQUARE INCH GAGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.358 INCHES MINIMUM AND 0.362 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SECOND FLANGE SINGLE CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.279 INCHES MINIMUM AND 0.282 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.139 INCHES MINIMUM AND 0.142 INCHES MAXIMUM |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.218 INCHES MINIMUM AND 0.222 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
CTFD | WAVEGUIDE LENGTH | 9.392 INCHES MINIMUM AND 9.412 INCHES MAXIMUM |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 2.328 INCHES MINIMUM AND 2.348 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT AND FLANGE |
PMLC | PRECIOUS MATERIAL AND LOCATION | EXTERNAL SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
SFTT | SURFACE TREATMENT | PRIMER SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | OFFSET BEND TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE SINGLE CONNECTION FACILITY |
ZZZV | FSC APPLICATION DATA | RADAR EQUIPMENT |