MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR DOUBLE RIDGED EXTERNAL,RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE THIRD TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SECOND TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM FIRST FLANGE AND 0.693 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.318 INCHES MINIMUM FIRST FLANGE AND 0.323 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.358 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.358 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM FIRST FLANGE AND 0.255 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.096 INCHES NOMINAL FIRST FLANGE SECOND CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.140 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.154 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.143 INCHES MINIMUM FIRST FLANGE FIRST CONNECTION FACILITY AND 0.149 INCHES MAXIMUM FIRST FLANGE FIRST CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.60 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.791 INCHES NOMINAL |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.693 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.323 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.421 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CONTACT,DOUBLE RIDGE TYPE FIRST FLANGE |
FEAT | SPECIAL FEATURES | FLANGES PRESSURIZED,FURNISHED W/ RF/ PRESSURE SEAL AND 0.625 IN. LG SCREW AND LOCKWASHER FOR EA MTG HOLE |
FLEX | FLEXIBILITY | FLEXIBLE FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | FLEXIBLE THIRD TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SECOND TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY SECOND TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY FIRST TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY THIRD TUBING SEGMENT |
MATT | MATERIAL | RUBBER CHLOROPRENE ALL TUBING JACKET OR RUBBER SILICONE ALL TUBING JACKET |
PMLC | PRECIOUS MATERIAL AND LOCATION | WAVEGUIDE SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
SFTT | SURFACE TREATMENT | SILVER FIRST TUBING SEGMENT ALL SURFACES |
SFTT | SURFACE TREATMENT | SILVER THIRD TUBING SEGMENT ALL SURFACES |
STYL | STYLE DESIGNATOR | FOUR BEND TYPE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |