MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AFZU | MAIN BODY INSIDE DIAMETER | 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZU | MAIN BODY INSIDE DIAMETER | 1.000 INCHES MINIMUM AS SUPPLIED |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.460 INCHES MINIMUM AS SUPPLIED |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.460 INCHES MINIMUM AS SUPPLIED |
AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.460 INCHES MINIMUM AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.770 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAC | FIRST BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAE | THIRD BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAF | FOURTH BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 2.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
FEAT | SPECIAL FEATURES | INSIDE ADHESIVE COATED |
HUES | COLOR | BLACK |
MATT | MATERIAL | RUBBER,POLYCHLOROPRENE,MIL-I-81765/2 |
STYL | STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 90.0 DEG CELSIUS |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.460 INCHES MINIMUM AS SUPPLIED |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZZ | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH | 2.830 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAD | SECOND BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |