Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-145-2494 (011452494) |
NCB Code | USA (01) |
Manufacturer | Nimikkeistokeskus Ncb Finland, Keytronics Inc, Ge Aviation Systems Ltd, Oeco Llc, B G Laboratories Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
10132845 | nimikkeistokeskus ncb finland | transformer power | a486g | RFQ |
5440 | keytronics inc | transformer power | 51181 | RFQ |
7109054-001 | ge aviation systems ltd | transformer power | 93322 | RFQ |
K5440 | keytronics inc | transformer power | 51181 | RFQ |
R104120A | oeco llc | transformer power | 98330 | RFQ |
S93A | b g laboratories inc | transformer power | 26522 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 57.0 WATTS SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.7 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 788.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 852.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 0.1 WATTS SINGLE COMPONENT ALL TERTIARY |
CRMJ | WINDING POWER RATING | 0.2 WATTS SINGLE COMPONENT 5TH WINDING |
CRMJ | WINDING POWER RATING | 22.0 WATTS SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 27.9 WATTS SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 33.3 WATTS SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 56.3 WATTS SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 13.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 27.90 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 7.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 6 SECONDARY WINDINGS; RECTIFIED CURRENT RATINGS GIVEN |
Components Related to NSN - 5950-01-145-2494, 5950011452494 | ||||
5905-00-502-3441 (5905005023441) | 5905-00-448-5537 (5905004485537) | 5940-00-621-2008 (5940006212008) | 5930-01-327-2312 (5930013272312) | |
5999-00-539-5784 (5999005395784) | 5905-01-313-7171 (5905013137171) | 5950-01-076-6980 (5950010766980) | 5965-01-571-2725 (5965015712725) | |
5920-01-501-5961 (5920015015961) | 5930-01-296-8547 (5930012968547) | 5996-00-048-2496 (5996000482496) | 5930-00-022-4311 (5930000224311) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.