Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-345-7472 (003457472) |
NCB Code | USA (00) |
Manufacturer | Lockheed Martin Corporation, General Electric Company |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.040 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.080 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.860 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.900 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.730 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 400.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 102.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 102.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY6.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY102.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 6.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY99.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY6.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 34.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 34.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY34.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC VOLTS |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 9 SOLDER STUD |
Components Related to NSN - 5950-00-345-7472, 5950003457472 | ||||
5999-01-481-1051 (5999014811051) | 5995-01-569-3777 (5995015693777) | 5998-00-302-2814 (5998003022814) | 5930-00-422-0534 (5930004220534) | |
5998-01-289-0549 (5998012890549) | 5962-00-274-2396 (5962002742396) | 5962-01-093-6792 (5962010936792) | 5930-01-169-8149 (5930011698149) | |
5940-01-042-9428 (5940010429428) | 5910-01-624-2225 (5910016242225) | 5998-01-456-1741 (5998014561741) | 5935-00-020-7903 (5935000207903) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote