Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 01-257-4018 (012574018) |
NCB Code | USA (01) |
Manufacturer | Cissell Manufacturing Company, Mcgeoch Technology Ltd, Parmatic Pollution Control, Cospolich Inc, Idec Systems And Controls Corp |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
2513-65 | cissell manufacturing company | relay electromagnetic | 12489 | RFQ |
6642 18 | mcgeoch technology ltd | relay electromagnetic | k7344 | RFQ |
6642 ITEM 18 | mcgeoch technology ltd | relay electromagnetic | k7344 | RFQ |
PC1284-1 | parmatic pollution control | relay electromagnetic | 63269 | RFQ |
PCCR33 | cospolich inc | relay electromagnetic | 66682 | RFQ |
RH1B-1-AC-120V | idec systems and controls corp | relay electromagnetic | 60886 | RFQ |
RH1B-U-AC-120V | idec systems and controls corp | relay electromagnetic | 60886 | RFQ |
RH1BU-AC120 | idec systems and controls corp | relay electromagnetic | 60886 | RFQ |
S1-25-006-A ITEM 20 | parmatic pollution control | relay electromagnetic | 63269 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 1.652 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.551 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AFRG | CONTACT MATERIAL | SILVER |
AGAV | END ITEM IDENTIFICATION | CONTROL PANEL |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 6.9 OHMS MINIMUM SINGLE WINDING AND 8.4 OHMS MAXIMUM SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 0.985 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 7.0 AMPERES AC INDUCTIVE LOAD AND 7.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
CWJB | ENERGIZING ELEMENT POWER RATING | 1.1 VOLTS-AMPERES |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
TTQY | TERMINAL TYPE AND QUANTITY | 5 QUICK DISCONNECT,MALE ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.082 INCHES MAXIMUM |
Components Related to NSN - 5945-01-257-4018, 5945012574018 | ||||
5998-00-404-5283 (5998004045283) | 5970-01-147-6559 (5970011476559) | 5905-01-619-3720 (5905016193720) | 5998-01-233-0410 (5998012330410) | |
5910-01-473-2951 (5910014732951) | 5910-01-337-0976 (5910013370976) | 5945-01-701-5176 (5945017015176) | 5962-01-293-2081 (5962012932081) | |
5995-01-500-4596 (5995015004596) | 5998-01-339-9359 (5998013399359) | 5935-00-005-2930 (5935000052930) | 5995-01-354-7490 (5995013547490) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.