Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 01-080-6186 (010806186) |
NCB Code | USA (01) |
Manufacturer | Genicom Corp, Dri Relays Inc, Allied Controls Inc, Hi G Co Inc, Military Specifications |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
3SAV1961A2 | genicom corp | relay electromagnetic | 01526 | RFQ |
DJ12N3J6AS-6M | dri relays inc | relay electromagnetic | 99699 | RFQ |
ERS6B3-12-0-M1 | allied controls inc | relay electromagnetic | 02288 | RFQ |
J2K-4730-111M | hi g co inc | relay electromagnetic | 02289 | RFQ |
M39016/6-111M | military specifications | relay electromagnetic | 81349 | RFQ |
M39016/6-211M | military specifications | relay electromagnetic | 81349 | RFQ |
MIL-PRF-39016/6 | military specifications | relay electromagnetic | 81349 | RFQ |
MIL-R-39016/6 | military specifications | relay electromagnetic | 81349 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.320 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.600 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.410 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 160.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 1.0 PERCENT; FLANGE MTG B |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 8 TAB,SOLDER LUG ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/6 GOVERNMENT SPECIFICATION |
Components Related to NSN - 5945-01-080-6186, 5945010806186 | ||||
5935-01-376-7509 (5935013767509) | 5965-01-666-8488 (5965016668488) | 5935-01-555-5092 (5935015555092) | 5975-01-685-8352 (5975016858352) | |
5998-01-392-3340 (5998013923340) | 5935-01-455-0919 (5935014550919) | 5935-01-087-5784 (5935010875784) | 5930-00-968-5115 (5930009685115) | |
5998-01-276-6482 (5998012766482) | 5962-01-169-3639 (5962011693639) | 5985-00-717-2726 (5985007172726) | 5935-01-353-1203 (5935013531203) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.