MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
35.0 AMPERES AC MOTOR LOAD AND 40.0 AMPERES DC MOTOR LOAD
CTDL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
40.0 AMPERES DC INDUCTIVE LOAD
CTDL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
55.0 AMPERES AC RESISTIVE LOAD AND 55.0 AMPERES DC RESISTIVE LOAD
CWAB
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS
115.0 AC AND 28.0 DC
TTQY
TERMINAL TYPE AND QUANTITY
6 THREADED STUD ALL FUNCTIONS
ZZZK
SPECIFICATION/STANDARD DATA
96906-MS24178 GOVERNMENT STANDARD
ABKQ
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY
ADZC
ENVIRONMENTAL PROTECTION
HERMETIC
AEBV
UNTHREADED MOUNTING HOLE DIAMETER
0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP
DUTY TYPE
CONTINUOUS
AXHR
MOUNTING FACILITY TYPE AND QUANTITY
2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CQYJ
MOUNTING FACILITY PATTERN
IN-LINE SINGLE MOUNTING FACILITY
CSXF
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP
28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TEST
TEST DATA DOCUMENT
81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN
Components Related to NSN - 5945-00-729-1358, 5945007291358