MRC | Criteria | Characteristic |
---|
AEBV | Unthreaded Mounting Hole Diameter | 0.281 INCHES NOMINAL |
MEDA | Media For Which Designed | LIQUID |
CQGB | Contact Action Stimulus | INCREASE |
ADAU | Body Height | 2.750 INCHES NOMINAL |
STYL | Style Designator | RECTANGULAR |
CQYJ | Mounting Facility Pattern | TWO POSITION IN-LINE |
ABKW | Overall Height | 6.093 INCHES NOMINAL |
AXGY | Mounting Method | UNTHREADED HOLE |
ABMK | Overall Width | 2.688 INCHES NOMINAL |
ABHP | Overall Length | 5.812 INCHES NOMINAL |
CTHF | Contact Load Current Rating | 1.0 AMPERES MOTOR LOAD SECOND VOLTAGE |
MRC | Decoded Requirement | Clear Text Reply |
AAJD | Thread Class | 2B SINGLE PRESSURE CONNECTION |
CTYM | Contact Adjustment Range | 25.00 TO 350.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE AND |
CTYM | Contact Adjustment Range | 25.00 TO 350.00 DEACTUATION POINT POUNDS PER SQUARE INCH GAGE |
CTYC | Contact Adjustability | DEACTUATION POINT ADJUSTABLE |
CTZB | Contact Voltage Rating In Volts | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTYS | Contact Adjustment Type | EXTERNAL ACTUATION POINT SCREW AND |
CTZB | Contact Voltage Rating In Volts | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
CQJB | Proof Pressure | 400.00 POUNDS PER SQUARE INCH GAGE |
CTZB | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZL | Pressure Connector Type | PLAIN, THREADED INTERNAL SINGLE CONNECTION |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
THSD | Thread Series Designator | UNF SINGLE PRESSURE CONNECTION |
CTYC | Contact Adjustability | ACTUATION POINT ADJUSTABLE AND |
CTYS | Contact Adjustment Type | EXTERNAL DEACTUATION POINT SCREW |
CTZB | Contact Voltage Rating In Volts | 230.0 DC AT SEA LEVEL FIFTH VOLTAGE |
AEJN | Distance Between Mounting Facility Centers | 5.250 INCHES NOMINAL |
CBBL | Features Provided | ELECTRICAL ACCESS PORT |
CQJX | Nominal Thread Size | 0.4375 INCHES SINGLE PRESSURE CONNECTION |
AJZC | Pressure Switch Type | GAGE |
CTHF | Contact Load Current Rating | 0.5 AMPERES MOTOR LOAD THIRD VOLTAGE |
CTHF | Contact Load Current Rating | 8.0 AMPERES RESISTIVE LOAD AND |
CTHF | Contact Load Current Rating | 15.0 AMPERES RESISTIVE LOAD AND |
CTHF | Contact Load Current Rating | 500.0 MILLIAMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | Contact Load Current Rating | 2.0 AMPERES MOTOR LOAD FIRST VOLTAGE |
CSCF | Terminal Type | SCREW |
CTHF | Contact Load Current Rating | 250.0 MILLIAMPERES RESISTIVE LOAD FIFTH VOLTAGE |
CTHF | Contact Load Current Rating | 12.0 AMPERES RESISTIVE LOAD AND |
MEDA | Media For Which Designed | GAS OR |
AXGY | Mounting Method | BRACKET AND |
AARX | Inside Diameter | 0.4375 INCHES NOMINAL SINGLE CONNECTION |
ABFE | Hazardous Locations/Environmental Protection | VIBRATION RESISTANT AND |
ABFE | Hazardous Locations/Environmental Protection | WATERTIGHT |