Item Name | Switch Pressure |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-838-0826 (008380826) |
NCB Code | USA (00) |
Manufacturer | Johnson Controls Inc, Trane Co The, Ellis And Watts International Llc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
10P7 | johnson controls inc | switch pressure | 92578 | RFQ |
210AP20 | johnson controls inc | switch pressure | 92578 | RFQ |
210AP20AN4401 | johnson controls inc | switch pressure | 92578 | RFQ |
210AP60AN | johnson controls inc | switch pressure | 92578 | RFQ |
4410-8814-1 | trane co the | switch pressure | 60532 | RFQ |
CNT209 | trane co the | switch pressure | 60532 | RFQ |
NC4-8 | ellis and watts international llc | switch pressure | 98437 | RFQ |
P20DA10 | johnson controls inc | switch pressure | 92578 | RFQ |
TYPE210AP60AN | johnson controls inc | switch pressure | 92578 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 3.313 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
CBBL | FEATURES PROVIDED | AUTOMATIC RESET |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED HOLE |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 360.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 450.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 90.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 2.875 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
AXGY | MOUNTING METHOD | BASE AND THREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL THREADED HOLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 14.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 7.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
Components Related to NSN - 5930-00-838-0826, 5930008380826 | ||||
5965-01-693-2274 (5965016932274) | 5970-00-117-7494 (5970001177494) | 5935-01-420-8935 (5935014208935) | 5930-01-259-4262 (5930012594262) | |
5998-00-918-9043 (5998009189043) | 5950-00-764-3188 (5950007643188) | 5985-00-834-2480 (5985008342480) | 5962-01-106-0873 (5962011060873) | |
5995-01-363-0307 (5995013630307) | 5985-00-273-1650 (5985002731650) | 5905-00-497-9173 (5905004979173) | 5998-01-100-7312 (5998011007312) | |