Item Name | Switch Pressure |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-615-8868 (006158868) |
NCB Code | USA (00) |
Manufacturer | Johnson Controls Inc, General Electric Company, Detroit Switch Inc, American Standard Inc, Hatch And Kirk Inc, General Motors Corp |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
025-08592 | johnson controls inc | switch pressure | 66935 | RFQ |
168A2434BHP1B | general electric company | switch pressure | 02989 | RFQ |
222-10NA1-2221044 | detroit switch inc | switch pressure | 19278 | RFQ |
222-10NA2-2221047 | american standard inc | switch pressure | 96452 | RFQ |
2221044 | detroit switch inc | switch pressure | 19278 | RFQ |
3325106 | hatch and kirk inc | switch pressure | 55380 | RFQ |
3325106 | general motors corp | switch pressure | 72915 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |
ABHP | OVERALL LENGTH | 5.906 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.688 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | BRACKET |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 4.6 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 1.00 TO 20.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL THIRD VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
Components Related to NSN - 5930-00-615-8868, 5930006158868 | ||||
5905-00-502-3441 (5905005023441) | 5905-00-448-5537 (5905004485537) | 5940-00-621-2008 (5940006212008) | 5930-01-327-2312 (5930013272312) | |
5999-00-539-5784 (5999005395784) | 5905-01-313-7171 (5905013137171) | 5950-01-076-6980 (5950010766980) | 5965-01-571-2725 (5965015712725) | |
5920-01-501-5961 (5920015015961) | 5930-01-296-8547 (5930012968547) | 5996-00-048-2496 (5996000482496) | 5930-00-022-4311 (5930000224311) | |