MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AASA | THREAD LENGTH | 0.469 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.828 INCHES NOMINAL |
ABNB | FIRST FLAT LENGTH | 0.313 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | FLAT HEIGHT | 0.188 INCHES NOMINAL SINGLE ACTUATOR |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | SHAFT LENGTH | 0.531 INCHES NOMINAL SINGLE ACTUATOR |
ADAV | OVERALL DIAMETER | 2.125 INCHES MINIMUM AND 2.205 INCHES MAXIMUM |
AFBH | INDIVIDUAL SECTION QUANTITY | 1 |
AFDC | NONTURN DEVICE TYPE | SLOTTED BUSHING AT 3:00 OCLOCK |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
AKPX | POLE QUANTITY | 1 SINGLE SECTION PERIPHERY |
AKPY | THROW QUANTITY | 3 SINGLE SECTION PERIPHERY |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.469 INCHES SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 125.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 15.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 250.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 30.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
CQRQ | SHAFT FLAT/SLOT ANGULAR LOCATION | 0.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 3 SINGLE ACTUATOR |
CRSJ | SHAFT TYPE | ROUND,FLATTED SINGLE ACTUATOR |
CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES SINGLE SECTION PERIPHERY |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 45.0 DEGREES SINGLE ACTUATOR |
CTDN | SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL AND 1.5 AMPERES INDUCTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL AND 1.5 AMPERES MOTOR LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL AND 2.5 AMPERES INDUCTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL AND 2.0 AMPERES LAMP LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL AND 3.0 AMPERES MOTOR LOAD HIGHEST DC V |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL AND 3.0 AMPERES INDUCTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL AND 1.0 AMPERES LAMP LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL AND 3.0 AMPERES MOTOR LOAD LOWEST AC VOLTA |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL AND 5.0 AMPERES INDUCTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL AND 2.0 AMPERES LAMP LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL AND 4.0 AMPERES MOTOR LOAD LOWEST DC VOLTA |
STYL | STYLE DESIGNATOR | TAP,CIRCULAR,BUSHING MOUNT |
THSD | THREAD SERIES DESIGNATOR | UNS SINGLE MOUNTING FACILITY |