Item Name | Switch Thermostatic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-272-1267 (002721267) |
NCB Code | USA (00) |
Manufacturer | Texas Instruments Inc, Sensata Technologies Inc, Harris Corporation, Lockheed Martin Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
20400D79-182 | texas instruments inc | switch thermostatic | 14859 | RFQ |
20400D79-182 | sensata technologies inc | switch thermostatic | 82647 | RFQ |
702050 | harris corporation | switch thermostatic | 31550 | RFQ |
702050-1 | harris corporation | switch thermostatic | 31550 | RFQ |
828171 | lockheed martin corporation | switch thermostatic | 56232 | RFQ |
C4370-13-1 | sensata technologies inc | switch thermostatic | 82647 | RFQ |
C4370-13-4 | sensata technologies inc | switch thermostatic | 82647 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.188 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.812 INCHES MINIMUM |
ABPM | BODY DIAMETER | 1.562 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.422 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.188 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.094 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.188 INCHES NOMINAL |
AFDW | SHORTEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.094 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AXGY | MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION DIAMOND |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 12.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 12.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 80.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 40.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL THIRD VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | DISC W/FLANGE |
Components Related to NSN - 5930-00-272-1267, 5930002721267 | ||||
5950-00-090-9508 (5950000909508) | 5995-01-203-9438 (5995012039438) | 5910-01-019-3189 (5910010193189) | 5910-00-107-4241 (5910001074241) | |
5905-01-061-7043 (5905010617043) | 5998-01-200-5542 (5998012005542) | 5995-01-006-0886 (5995010060886) | 5998-01-393-1676 (5998013931676) | |
5998-00-560-0747 (5998005600747) | 5985-00-087-4949 (5985000874949) | 5950-01-258-0567 (5950012580567) | 5940-00-852-3386 (5940008523386) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.