Item Name | Circuitbreaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-317-0487 (013170487) |
NCB Code | USA (01) |
Manufacturer | Klockner Moeller Corp |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
NZM6B-63 ZM6-12-80-OBI-CNA CL6 | klockner moeller corp | circuitbreaker | 57715 | RFQ |
NZM6B63ZM612800BICNA | klockner moeller corp | circuitbreaker | 57715 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABHP | OVERALL LENGTH | 210.0 MILLIMETERS NOMINAL |
ABKW | OVERALL HEIGHT | 180.0 MILLIMETERS NOMINAL |
ABMK | OVERALL WIDTH | 110.0 MILLIMETERS NOMINAL |
ADAQ | BODY LENGTH | 280.5 MILLIMETERS NOMINAL |
ADAT | BODY WIDTH | 252.0 MILLIMETERS NOMINAL |
ADAU | BODY HEIGHT | 110.0 MILLIMETERS NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 252.0 MILLIMETERS NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 95.0 MILLIMETERS NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 210.0 MILLIMETERS NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 95.0 MILLIMETERS NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 16.0 MILLIMETERS NOMINAL |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 TERMINAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE AND CURRENT LIMITER |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 12.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 14000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | UNDERVOLTAGE ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 ROTARY |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | 40.0 TO 80.0 AC ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
Components Related to NSN - 5925-01-317-0487, 5925013170487 | ||||
5915-01-618-2870 (5915016182870) | 5975-01-387-5612 (5975013875612) | 5998-01-420-9446 (5998014209446) | 5962-01-024-4400 (5962010244400) | |
5999-01-564-5586 (5999015645586) | 5925-00-880-0235 (5925008800235) | 5930-01-352-5157 (5930013525157) | 5995-01-659-3389 (5995016593389) | |
5935-01-695-1605 (5935016951605) | 5950-01-263-3588 (5950012633588) | 5998-01-178-2838 (5998011782838) | 5998-01-271-2125 (5998012712125) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.