INSTANT RFQ

Explore Our NSN 5915-01-228-8710 Parts List

Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 01-228-8710 (012288710)
NCB Code USA (01)
Manufacturer Raytheon Company, Corcom Inc
Part Number Manufacturer Item Name Cage Code RFQ
731012-1 raytheon company filter radio frequency interfere 05869 RFQ
NF21264 corcom inc filter radio frequency interfere 05245 RFQ
NF21292 corcom inc filter radio frequency interfere 05245 RFQ

Technical Characteristics of NSN 5915012288710

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH18.000 INCHES NOMINAL
ABKWOVERALL HEIGHT7.370 INCHES NOMINAL
ADAQBODY LENGTH16.000 INCHES NOMINAL
ADATBODY WIDTH4.000 INCHES NOMINAL
ADAUBODY HEIGHT6.000 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.256 INCHES MINIMUM AND 0.263 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH17.250 INCHES NOMINAL
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 55.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH5.250 INCHES NOMINAL
AFSVAVERAGE LIFE RATING IN HOURS250.0
AGAVEND ITEM IDENTIFICATIONRECEIVING SET,SONAR AN/SQR-18A(V)
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 2ND RADIO INTERFERENCE 2ND FUNCTION63.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 3RD RADIO INTERFERENCE 3RD FUNCTION63.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 4TH RADIO INTERFERENCE 4TH FUNCTION63.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 5TH RADIO INTERFERENCE 5TH FUNCTION63.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 6TH RADIO INTERFERENCE 6TH FUNCTION63.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 2ND RADIO INTERFERENCE 2ND FUNCTION20.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 3RD RADIO INTERFERENCE 3RD FUNCTION20.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 4TH RADIO INTERFERENCE 4TH FUNCTION20.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 5TH RADIO INTERFERENCE 5TH FUNCTION20.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 6TH RADIO INTERFERENCE 6TH FUNCTION20.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE 2ND FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE 3RD FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 4TH RADIO INTERFERENCE 4TH FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 5TH RADIO INTERFERENCE 5TH FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 6TH RADIO INTERFERENCE 6TH FUNCTION INDUCTANCE-CAPACITANCE-RESISTANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE96906
AHBPINPUT TERMINAL IDENTIFICATIONMS3400D22-23P
AHBXDISTANCE BETWEEN MOUNTING SURFACE AND LOWER END3.750 INCHES NOMINAL
AHCGMAXIMUM TEMP RISE60.0 DEG CELSIUS
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITY24 UNTHREADED HOLE ALL FUNCTIONS
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY6 PIN OUTPUT 2ND FUNCTION6 PIN OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION
CQRGBODY MATERIALMETAL
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE600.0 VOLTS AT SEA LEVEL
CTJSUNPACKAGED UNIT WEIGHT25.000 POUNDS NOMINAL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES

Components Related to NSN - 5915-01-228-8710, 5915012288710
5950-00-782-4837 (5950007824837) 5905-01-053-5779 (5905010535779) 5962-01-037-6404 (5962010376404) 5995-01-204-1471 (5995012041471)
5970-01-146-4146 (5970011464146) 5975-01-393-2233 (5975013932233) 5999-01-420-7755 (5999014207755) 5910-00-826-2725 (5910008262725)
5998-01-303-6935 (5998013036935) 5935-01-273-2470 (5935012732470) 5935-01-172-3967 (5935011723967) 5999-01-176-2149 (5999011762149)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top