INSTANT RFQ

Explore Our NSN 5915-00-880-2193 Parts List

Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 00-880-2193 (008802193)
NCB Code USA (00)
Manufacturer General Dynamics Advanced, Military Specifications
Part Number Manufacturer Item Name Cage Code RFQ
32-805380-1 general dynamics advanced filter radio frequency interfere 07397 RFQ
FL53DD1EA1 military specifications filter radio frequency interfere 81349 RFQ
M15733/04-0001 military specifications filter radio frequency interfere 81349 RFQ
MIL-F-15733/4 military specifications filter radio frequency interfere 81349 RFQ

Technical Characteristics of NSN 5915008802193

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH3.406 INCHES MAXIMUM
ADAQBODY LENGTH1.750 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 2000.0
AFGAOPERATING TEMP RANGE-65.0 TO 85.0 DEG CELSIUS
AFSVAVERAGE LIFE RATING IN HOURS250.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB,SOLDER LUG INPUT 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
ADATBODY WIDTH1.250 INCHES NOMINAL
ADAUBODY HEIGHT0.875 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.125 INCHES NOMINAL
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 BLANK
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION500.0 MILLIVOLTS DC BLANK
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB,SOLDER LUG OUTPUT 2ND FUNCTION
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT SEA LEVEL
TESTTEST DATA DOCUMENT81349-MILF15733-4C SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECT

Components Related to NSN - 5915-00-880-2193, 5915008802193
5950-00-782-4837 (5950007824837) 5905-01-053-5779 (5905010535779) 5962-01-037-6404 (5962010376404) 5995-01-204-1471 (5995012041471)
5970-01-146-4146 (5970011464146) 5975-01-393-2233 (5975013932233) 5999-01-420-7755 (5999014207755) 5910-00-826-2725 (5910008262725)
5998-01-303-6935 (5998013036935) 5935-01-273-2470 (5935012732470) 5935-01-172-3967 (5935011723967) 5999-01-176-2149 (5999011762149)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top