Technical Characteristics of NSN 5915005938208

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH7.000 INCHES NOMINAL
ADAQBODY LENGTH5.000 INCHES NOMINAL
ADATBODY WIDTH4.000 INCHES MAXIMUM
ADAUBODY HEIGHT2.000 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.170 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH6.000 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.500 INCHES NOMINAL
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 6TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 2ND RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 4TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 5TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 1ST RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 3RD RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 5TH RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY6 THREADED STUD OUTPUT 2ND FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY6 WIRE LEAD INPUT 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION24.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION24.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION24.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION24.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION24.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION24.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION
CQRGBODY MATERIALMETAL
CRSTBODY SURFACE TREATMENTTIN
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES

Components Related to NSN - 5915-00-593-8208, 5915005938208
5950-00-090-9508 (5950000909508) 5995-01-203-9438 (5995012039438) 5910-01-019-3189 (5910010193189) 5910-00-107-4241 (5910001074241)
5905-01-061-7043 (5905010617043) 5998-01-200-5542 (5998012005542) 5995-01-006-0886 (5995010060886) 5998-01-393-1676 (5998013931676)
5998-00-560-0747 (5998005600747) 5985-00-087-4949 (5985000874949) 5950-01-258-0567 (5950012580567) 5940-00-852-3386 (5940008523386)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top