Item Name | Capacitor Fixed Ceramic Dielectr |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5910 Capacitors |
National Item Identification Number (NIIN) | 01-221-8974 (012218974) |
NCB Code | USA (01) |
Manufacturer | Rockwell Collins Aerospace, Kemet Electronics Corporation, Military Specifications, Avx Corporation, West Cap Arizona |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
913-5028-210 | rockwell collins aerospace | capacitor fixed ceramic dielectr | 13499 | RFQ |
C052C569D2G5CA | kemet electronics corporation | capacitor fixed ceramic dielectr | 31433 | RFQ |
CCR05CH5R6CR | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
CCR05CH5R6CS | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
CCR05CH5R6DP | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
CCR05CH5R6DR | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
CCR05CH5R6JM | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
CCR05CJ5R6CP | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
CCR05CJ5R6CS | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
MIL-C-20/35 | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
MIL-PRF-20/35 | military specifications | capacitor fixed ceramic dielectr | 81349 | RFQ |
MR055A5R6DAA | avx corporation | capacitor fixed ceramic dielectr | 04222 | RFQ |
R3500-210 | west cap arizona | capacitor fixed ceramic dielectr | 32159 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.0010 |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.190 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.190 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.090 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.200 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.020 INCHES MINIMUM AND 0.027 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 10000.0 MEGOHMS |
CQBQ | CAPACITANCE VALUE PER SECTION | 5.600 PICOFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 200.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -120.0/120.0 SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -0.25 TO 0.25 PICOFARADS SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.1500 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-20/35 GOVERNMENT SPECIFICATION |
Components Related to NSN - 5910-01-221-8974, 5910012218974 | ||||
5935-00-789-6206 (5935007896206) | 5999-00-195-5441 (5999001955441) | 5930-00-426-2671 (5930004262671) | 5935-01-210-1780 (5935012101780) | |
5990-01-114-9896 (5990011149896) | 5925-01-198-7912 (5925011987912) | 5995-01-152-5092 (5995011525092) | 5910-00-989-4896 (5910009894896) | |
5961-00-172-8326 (5961001728326) | 5950-00-971-5673 (5950009715673) | 5925-00-235-0046 (5925002350046) | 5962-01-421-9559 (5962014219559) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.