Item Name | Capacitor Fixed Glass Dielectric |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5910 Capacitors |
National Item Identification Number (NIIN) | 00-137-4806 (001374806) |
NCB Code | USA (00) |
Manufacturer | Northrop Grumman Systems Corporation, Military Specifications, Corning Cable Systems Llc, Avx Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
577R559H63 | northrop grumman systems corporation | capacitor fixed glass dielectric | 97942 | RFQ |
CY06C102J | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
CY07C102J | corning cable systems llc | capacitor fixed glass dielectric | 12290 | RFQ |
CY07C102K | avx corporation | capacitor fixed glass dielectric | 16299 | RFQ |
CY07G102G | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
CYR52C102FM | avx corporation | capacitor fixed glass dielectric | 16299 | RFQ |
M23269-10-2218 | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
M23269-10-5218 | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
M23269/10-2216 | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
M23269/10-3216 | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
M23269/10-3218 | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
MIL-PRF-23269/10 | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
MILC23269-10 | military specifications | capacitor fixed glass dielectric | 81349 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | D |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.0000 |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.300 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.300 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.115 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.200 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 10000.0 MEGOHMS |
CQBQ | CAPACITANCE VALUE PER SECTION | 1000.000 PICOFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 140.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 300.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -25.0 TO 25.0 SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -1.00 TO 1.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.1000 |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACE GOLD |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-23269 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-23269/10 GOVERNMENT SPECIFICATION |
Components Related to NSN - 5910-00-137-4806, 5910001374806 | ||||
5940-00-954-7451 (5940009547451) | 5998-00-230-4690 (5998002304690) | 5999-01-314-3186 (5999013143186) | 5961-00-671-3017 (5961006713017) | |
5962-01-468-3171 (5962014683171) | 5930-01-462-7010 (5930014627010) | 5975-01-213-2865 (5975012132865) | 5998-01-663-9810 (5998016639810) | |
5910-01-239-2035 (5910012392035) | 5999-01-048-9702 (5999010489702) | 5985-00-665-4910 (5985006654910) | 5998-01-432-8434 (5998014328434) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote