Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 01-100-6872 (011006872) |
NCB Code | USA (01) |
Manufacturer | Struthers Dunn Inc, Decision Data Computer Corp, Raytheon Company, Military Specifications, Vishay Dale Electronics Inc, Tepro Of Florida Inc, Clarostat Sensors And Controls |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
1500S301-1 | struthers dunn inc | resistor fixed wire wound induct | 00213 | RFQ |
1627-35 | decision data computer corp | resistor fixed wire wound induct | 57583 | RFQ |
27-457 | raytheon company | resistor fixed wire wound induct | 49956 | RFQ |
MIL-PRF-39007/6 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
MIL-R-39007/6 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RS5-3010F | vishay dale electronics inc | resistor fixed wire wound induct | 91637 | RFQ |
RS500B301R0F | vishay dale electronics inc | resistor fixed wire wound induct | 91637 | RFQ |
RWR74S3000FM | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RWR74S3010FM | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RWR74S3010FP | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RWR74S3010FR | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RWR74S3010FS | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
TS5W3010F | tepro of florida inc | resistor fixed wire wound induct | 15915 | RFQ |
VC5E300R0J | clarostat sensors and controls | resistor fixed wire wound induct | 12697 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 301.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.312 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.875 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 5.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CSCF | TERMINAL TYPE | WIRE LEAD |
PKWT | UNPACKAGED UNIT WEIGHT | 5.000 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-39007/6 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFL |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-39007/6 GOVERNMENT SPECIFICATION |
Components Related to NSN - 5905-01-100-6872, 5905011006872 | ||||
5998-01-426-5075 (5998014265075) | 5950-01-028-6707 (5950010286707) | 5975-01-323-0674 (5975013230674) | 5998-00-444-2908 (5998004442908) | |
5998-01-670-0290 (5998016700290) | 5905-01-099-4430 (5905010994430) | 5930-01-046-8141 (5930010468141) | 5995-01-460-6411 (5995014606411) | |
5910-00-617-3236 (5910006173236) | 5995-01-619-5989 (5995016195989) | 5935-01-259-1269 (5935012591269) | 5985-01-265-5129 (5985012655129) | |