MRC | Criteria | Characteristic |
---|
ADAT | BODY WIDTH | 0.250 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.190 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | LADDER NETWORK |
AEFB | POWER DISSIPATION RATING IN WATTS | 1.950 TOTAL NETWORK |
AFWW | TERMINAL WIDTH | 0.018 INCHES NOMINAL |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 2ND INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 3RD INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 4TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 5TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 6TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 7TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 8TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 9TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
STYL | STYLE DESIGNATOR | DUAL INLINE |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -200.0/200.0 |
AAPP | III ELECTRICAL RESISTANCE | 1.000 KILOHMS LOWEST RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.023 KILOHMS 1ST INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.047 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.072 KILOHMS 3RD INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.096 KILOHMS 4TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.122 KILOHMS 5TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.148 KILOHMS 6TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.175 KILOHMS 7TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.202 KILOHMS 8TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 1.230 KILOHMS 9TH INTERMEDIATE RESISTANCE VALUE |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 EACH RESISTOR |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 125.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 14 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.135 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.750 INCHES NOMINAL |