Item Name | Resistor Fixed Film |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-758-3115 (007583115) |
NCB Code | USA (00) |
Manufacturer | Lucas Aerospace Ltd, Lh Enterprise, Cooper Crouse Hinds Llc, Autek Systems Corp, Thales Defense And Security Inc, Drs Power And Control Technologies, Bendix Corp, Spacelabs Hillsboro Operations, Northrop Grumman Systems Corporation, Boeing Company The, Military Specifications, Thomson Multimedia Broadcast, Rockwell Collins Aerospace, Hubbell Harvey Inc, Lockheed Martin Corporation, Butler National Corp, Trw Limited, Vishay Dale Electronics Inc, Allen Robert G Inc, Hughes Corporation, International Resistive Company Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
03-0005-227 | lucas aerospace ltd | resistor fixed film | 31435 | RFQ |
061-02006-000 | lh enterprise | resistor fixed film | 12131 | RFQ |
10047-691-2003 | cooper crouse hinds llc | resistor fixed film | 18192 | RFQ |
107-0530 | autek systems corp | resistor fixed film | 54817 | RFQ |
107-530 | autek systems corp | resistor fixed film | 54817 | RFQ |
134584-0004 | thales defense and security inc | resistor fixed film | 65597 | RFQ |
200-1533795-354 | drs power and control technologies | resistor fixed film | 27192 | RFQ |
200-1533795-354 | bendix corp | resistor fixed film | 06840 | RFQ |
321-0414-00 | spacelabs hillsboro operations | resistor fixed film | 59873 | RFQ |
437-042003-023 | northrop grumman systems corporation | resistor fixed film | 26916 | RFQ |
443-1178-414 | boeing company the | resistor fixed film | 94756 | RFQ |
4703-0414-00 | military specifications | resistor fixed film | 81349 | RFQ |
69-032679-061 | thomson multimedia broadcast | resistor fixed film | 32791 | RFQ |
705-1471-230 | rockwell collins aerospace | resistor fixed film | 13499 | RFQ |
747-2003 | hubbell harvey inc | resistor fixed film | 22818 | RFQ |
7904192-413 | lockheed martin corporation | resistor fixed film | 90536 | RFQ |
B122362-0004 | butler national corp | resistor fixed film | 30184 | RFQ |
CEAT0-204F | trw limited | resistor fixed film | 75042 | RFQ |
CEATOP2003F | trw limited | resistor fixed film | 75042 | RFQ |
CMF-55 2003F T-1 | vishay dale electronics inc | resistor fixed film | 91637 | RFQ |
MF25D2003F | allen robert g inc | resistor fixed film | 6l611 | RFQ |
MFF1-8204F | vishay dale electronics inc | resistor fixed film | 91637 | RFQ |
MFF1816G20002F | vishay dale electronics inc | resistor fixed film | 91637 | RFQ |
MIL-PRF-55182/1 | military specifications | resistor fixed film | 81349 | RFQ |
MIL-R-55182/1 | military specifications | resistor fixed film | 81349 | RFQ |
R01D090 ITEM 12 | hughes corporation | resistor fixed film | 6z382 | RFQ |
RN55D1993F | military specifications | resistor fixed film | 81349 | RFQ |
RNC55K2003FR | military specifications | resistor fixed film | 81349 | RFQ |
RNC55K2003FS | military specifications | resistor fixed film | 81349 | RFQ |
RNR55K2002FS | military specifications | resistor fixed film | 81349 | RFQ |
RNR55K2003FP | military specifications | resistor fixed film | 81349 | RFQ |
RNR55K2003FS | military specifications | resistor fixed film | 81349 | RFQ |
T055-200000-1F | international resistive company inc | resistor fixed film | 11502 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0 TO 100.0 |
AAPP | ELECTRICAL RESISTANCE | 200.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.078 INCHES MINIMUM AND 0.140 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS |
PKWT | UNPACKAGED UNIT WEIGHT | 0.35 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-55182/1 GOVERNMENT SPECIFICATION |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 175.0 |
AARB | TERMINAL TYPE | WIRE LEAD |
ADAQ | BODY LENGTH | 0.204 INCHES MINIMUM AND 0.281 INCHES MAXIMUM |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-55182 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
Components Related to NSN - 5905-00-758-3115, 5905007583115 | ||||
5965-01-693-2274 (5965016932274) | 5970-00-117-7494 (5970001177494) | 5935-01-420-8935 (5935014208935) | 5930-01-259-4262 (5930012594262) | |
5998-00-918-9043 (5998009189043) | 5950-00-764-3188 (5950007643188) | 5985-00-834-2480 (5985008342480) | 5962-01-106-0873 (5962011060873) | |
5995-01-363-0307 (5995013630307) | 5985-00-273-1650 (5985002731650) | 5905-00-497-9173 (5905004979173) | 5998-01-100-7312 (5998011007312) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote