Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-504-4625 (005044625) |
NCB Code | USA (00) |
Manufacturer | Heico Ohmite Llc, Hamilton Sundstrand Corporation, Sundstrand International Corporation, Westinghouse Electric Corp, Resistors Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
36878-3 | heico ohmite llc | resistor fixed wire wound induct | 44655 | RFQ |
P19C7498-3 | hamilton sundstrand corporation | resistor fixed wire wound induct | 99167 | RFQ |
P19C7498-3 | sundstrand international corporation | resistor fixed wire wound induct | 83843 | RFQ |
P19C7498-3 | westinghouse electric corp | resistor fixed wire wound induct | 79500 | RFQ |
R4934-3 | resistors inc | resistor fixed wire wound induct | 83827 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -400.0 TO 400.0-400.0 TO 400.0-400.0 TO 400.0-400.0 TO 400.0-400.0 TO 400.0-400.0 TO 400.0 |
AAPP | ELECTRICAL RESISTANCE | 1.200 KILOHMS1.200 KILOHMS1.200 KILOHMS1.200 KILOHMS1.200 KILOHMS1.200 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000-5.000 TO 5.000-5.000 TO 5.000-5.000 TO 5.000-5.000 TO 5.000-5.000 TO 5.000 |
AAPR | FIXED TAP QUANTITY | 111111 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 325.0325.0325.0325.0325.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 330.0-65.0 TO 330.0-65.0 TO 330.0-65.0 TO 330.0-65.0 TO 330.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.391 INCHES NOMINAL0.391 INCHES NOMINAL0.391 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.750 INCHES NOMINAL1.750 INCHES NOMINAL1.750 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 10.000 FREE AIR10.000 FREE AIR10.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS25.0 DEG CELSIUS25.0 DEG CELSIUS |
AFWW | TERMINAL WIDTH | 0.219 INCHES NOMINAL0.219 INCHES NOMINAL0.219 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | ENCAPSULATEDENCAPSULATEDENCAPSULATED |
CQFD | SECTION NOMINAL RESISTANCE | 500.000 OHMS 1ST SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 700.000 OHMS 2ND SECTIONUNABLE TO DECODE |
CQFK | FIXED TAP TERMINAL TYPE | TAB,SOLDER LUGTAB,SOLDER LUG |
CSCF | TERMINAL TYPE | TAB,SOLDER LUGTAB,SOLDER LUG |
STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 83843-19C7498 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
Components Related to NSN - 5905-00-504-4625, 5905005044625 | ||||
5998-00-404-5283 (5998004045283) | 5970-01-147-6559 (5970011476559) | 5905-01-619-3720 (5905016193720) | 5998-01-233-0410 (5998012330410) | |
5910-01-473-2951 (5910014732951) | 5910-01-337-0976 (5910013370976) | 5945-01-701-5176 (5945017015176) | 5962-01-293-2081 (5962012932081) | |
5995-01-500-4596 (5995015004596) | 5998-01-339-9359 (5998013399359) | 5935-00-005-2930 (5935000052930) | 5995-01-354-7490 (5995013547490) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.