Item Name | Resistor Fixed Film |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-112-2181 (001122181) |
NCB Code | USA (00) |
Manufacturer | Mepco Electra Inc, Navair And Navsea Managed, Rockwell Collins Aerospace, Leonardo Spa Airborne And Space, Alenia Sistemi Difesa Spa, Kearfott Corporation, Military Specifications |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
10042 | mepco electra inc | resistor fixed film | 80031 | RFQ |
1820944-320 | navair and navsea managed | resistor fixed film | 10001 | RFQ |
724-0630-580 | rockwell collins aerospace | resistor fixed film | 95105 | RFQ |
724-0639-260 | rockwell collins aerospace | resistor fixed film | 95105 | RFQ |
912-3103-0639 | leonardo spa airborne and space | resistor fixed film | a0810 | RFQ |
912-3103-0639 | alenia sistemi difesa spa | resistor fixed film | a0307 | RFQ |
C600014042 | kearfott corporation | resistor fixed film | 88818 | RFQ |
MIL-PRF-55182/1 | military specifications | resistor fixed film | 81349 | RFQ |
MILR55182-1 | military specifications | resistor fixed film | 81349 | RFQ |
RNC55H2101FM | military specifications | resistor fixed film | 81349 | RFQ |
RNC55H2101FP | military specifications | resistor fixed film | 81349 | RFQ |
RNC55H2101FR | military specifications | resistor fixed film | 81349 | RFQ |
RNC55H2101FS | military specifications | resistor fixed film | 81349 | RFQ |
RNR55H2101FM | military specifications | resistor fixed film | 81349 | RFQ |
RNR55H2101FR | military specifications | resistor fixed film | 81349 | RFQ |
RNR55H2101FS | military specifications | resistor fixed film | 81349 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
AAPP | ELECTRICAL RESISTANCE | 2.100 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 175.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.109 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-55182 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
Components Related to NSN - 5905-00-112-2181, 5905001122181 | ||||
5925-01-622-1713 (5925016221713) | 5950-00-224-8269 (5950002248269) | 5999-00-940-2834 (5999009402834) | 5945-00-963-1183 (5945009631183) | |
5940-00-615-5893 (5940006155893) | 5998-00-297-6935 (5998002976935) | 5950-00-646-2937 (5950006462937) | 5961-00-228-5860 (5961002285860) | |
5935-01-107-8942 (5935011078942) | 5945-01-131-3787 (5945011313787) | 5998-01-373-2457 (5998013732457) | 5950-01-276-8859 (5950012768859) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.