Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-100-4141 (001004141) |
NCB Code | USA (00) |
Manufacturer | Harsco Corporation, Science Applications International Corporation, Heico Ohmite Llc, Lockheed Martin Corporation, Stromberg Carlson Corp, Kurz And Root Generator Company Llc, Cegelec Automation Inc, Electric Machinery, Kato Engineering Inc, General Electric Company |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
00155-107 | harsco corporation | resistor fixed wire wound induct | 93568 | RFQ |
00155-107 | science applications international corporation | resistor fixed wire wound induct | 79343 | RFQ |
00664-0197 | science applications international corporation | resistor fixed wire wound induct | 79343 | RFQ |
00664-0197 | harsco corporation | resistor fixed wire wound induct | 93568 | RFQ |
0400B | heico ohmite llc | resistor fixed wire wound induct | 44655 | RFQ |
0400B100HM | heico ohmite llc | resistor fixed wire wound induct | 44655 | RFQ |
155-0017 | harsco corporation | resistor fixed wire wound induct | 93568 | RFQ |
2006-9001 | lockheed martin corporation | resistor fixed wire wound induct | 08241 | RFQ |
554547-100 | stromberg carlson corp | resistor fixed wire wound induct | 14100 | RFQ |
559PA2715 | kurz and root generator company llc | resistor fixed wire wound induct | 75377 | RFQ |
664-197 | harsco corporation | resistor fixed wire wound induct | 93568 | RFQ |
800A241F02 | cegelec automation inc | resistor fixed wire wound induct | 60451 | RFQ |
800A241F02 | electric machinery | resistor fixed wire wound induct | 19899 | RFQ |
865-21044-73 | kato engineering inc | resistor fixed wire wound induct | 32770 | RFQ |
A50BB | general electric company | resistor fixed wire wound induct | 03508 | RFQ |
A50BB10 | general electric company | resistor fixed wire wound induct | 03508 | RFQ |
L50J10R | heico ohmite llc | resistor fixed wire wound induct | 44655 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -400.0 TO 400.0 |
AAPP | ELECTRICAL RESISTANCE | 10.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 350.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.562 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.562 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.000 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.750 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 50.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
BYML | MOUNTING HOLE SIZE | 0.161 INCHES NOMINAL |
CBME | CUBIC MEASURE | 0.992 CUBIC INCHES |
CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH END |
Components Related to NSN - 5905-00-100-4141, 5905001004141 | ||||
5999-01-481-1051 (5999014811051) | 5995-01-569-3777 (5995015693777) | 5998-00-302-2814 (5998003022814) | 5930-00-422-0534 (5930004220534) | |
5998-01-289-0549 (5998012890549) | 5962-00-274-2396 (5962002742396) | 5962-01-093-6792 (5962010936792) | 5930-01-169-8149 (5930011698149) | |
5940-01-042-9428 (5940010429428) | 5910-01-624-2225 (5910016242225) | 5998-01-456-1741 (5998014561741) | 5935-00-020-7903 (5935000207903) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.