Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-080-3218 (000803218) |
NCB Code | USA (00) |
Manufacturer | Lockheed Martin Corporation, Gould Instrument Systems Inc, Autek Systems Corp, General Electric Company, Thales Nederland Bv, Thales Cryogenics B V, Motorola Inc, Rockwell Collins Aerospace, Union Technique Electricite, Trw Limited, Hewlett-Packard Company, R F Products Inc, Vishay Dale Electronics Inc, Raytheon Company, Joint Army-Navy Specifications, Military Specifications |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
050-17 | lockheed martin corporation | resistor fixed wire wound induct | 56232 | RFQ |
055-9 | lockheed martin corporation | resistor fixed wire wound induct | 56232 | RFQ |
10-243484-47 | gould instrument systems inc | resistor fixed wire wound induct | 96795 | RFQ |
114-0047 | autek systems corp | resistor fixed wire wound induct | 54817 | RFQ |
19B209022P131 | general electric company | resistor fixed wire wound induct | 08771 | RFQ |
337708-041 | lockheed martin corporation | resistor fixed wire wound induct | 56232 | RFQ |
352250000155 | thales nederland bv | resistor fixed wire wound induct | h0203 | RFQ |
432208050300 | thales cryogenics b v | resistor fixed wire wound induct | h1418 | RFQ |
6-124061 | motorola inc | resistor fixed wire wound induct | 94990 | RFQ |
6-124D61 | motorola inc | resistor fixed wire wound induct | 94990 | RFQ |
747-5368-000 | rockwell collins aerospace | resistor fixed wire wound induct | 95105 | RFQ |
BB59V4U7J | union technique electricite | resistor fixed wire wound induct | f0115 | RFQ |
BWH 4 7 OHMS 5 | trw limited | resistor fixed wire wound induct | 75042 | RFQ |
BWH2-4R7J | hewlett-packard company | resistor fixed wire wound induct | 28480 | RFQ |
BWH2-4R7J | trw limited | resistor fixed wire wound induct | 75042 | RFQ |
BWH4-7 | trw limited | resistor fixed wire wound induct | 75042 | RFQ |
BWH4-70HMP0RM10PCT | trw limited | resistor fixed wire wound induct | 75042 | RFQ |
BWH4-7OHM5PCT | r f products inc | resistor fixed wire wound induct | 58022 | RFQ |
CW-2C-1 | vishay dale electronics inc | resistor fixed wire wound induct | 91637 | RFQ |
F00001-46 | raytheon company | resistor fixed wire wound induct | 96214 | RFQ |
JANR184 | joint army-navy specifications | resistor fixed wire wound induct | 81350 | RFQ |
MIL-PRF-26/4 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
MIL-R-26/4 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RU3B4R7J | joint army-navy specifications | resistor fixed wire wound induct | 81350 | RFQ |
RW59V4R5 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RW59V4R7 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RW67V497 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RW69V4R7 | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
RW69V4R7J | military specifications | resistor fixed wire wound induct | 81349 | RFQ |
VBE608V4E7 | thales nederland bv | resistor fixed wire wound induct | h0203 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -400.0 TO 400.0 |
AAPP | ELECTRICAL RESISTANCE | 4.700 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 350.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 2.125 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.125 INCHES MINIMUM AND 0.251 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.437 INCHES MINIMUM AND 0.563 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CBME | CUBIC MEASURE | 0.028 CUBIC INCHES |
CSCF | TERMINAL TYPE | WIRE LEAD |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-26 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-26/4 GOVERNMENT SPECIFICATION |
Components Related to NSN - 5905-00-080-3218, 5905000803218 | ||||
5999-01-481-1051 (5999014811051) | 5995-01-569-3777 (5995015693777) | 5998-00-302-2814 (5998003022814) | 5930-00-422-0534 (5930004220534) | |
5998-01-289-0549 (5998012890549) | 5962-00-274-2396 (5962002742396) | 5962-01-093-6792 (5962010936792) | 5930-01-169-8149 (5930011698149) | |
5940-01-042-9428 (5940010429428) | 5910-01-624-2225 (5910016242225) | 5998-01-456-1741 (5998014561741) | 5935-00-020-7903 (5935000207903) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote